Status: implemented, in issue #231. How to use it is in the guide. The code is config.py.

The numbers that tune a whole deployment, and where they are set. What each one does is in the spec that owns the thing it tunes (the runner, submitted jobs, skills, observers).

Goal

A setting that applies to a whole deployment is set where a deployment is configured: the environment. One that you also change by hand, while you try something out, can be passed in code. And there is one list: every variable featherweight reads has the prefix FTW_, is in the table below, and is read by one function, so there is no variable that you find only by reading the code.

The rule

  • Every environment variable of featherweight starts with FTW_. (The keys of the model providers, the names that an MCP server's env_from and headers_from point to, and OpenTelemetry's own OTEL_INSTRUMENTATION_GENAI_CAPTURE_CONTENT are not featherweight's, and keep their names.)
  • Two kinds of setting.
  • Both ways: the argument of the constructor wins; if there is none, the variable; if there is none, the default. These are the numbers you change by hand when you try something out: how many attempts run at once, how far agents launch agents, how many jobs a worker runs at once.
  • Environment only: the variable, else the default. There is no constructor argument. These are the numbers that tune a platform and that nobody sets for one worker: leases, timeouts, polling.
  • Read when the object is built, not at import, and kept as an attribute. A test sets the variable, then builds the runner or the worker. A change of the variable later does not reach an object that exists.
  • A variable that is set but empty counts as not set, for a number and for FTW_LOG_LEVEL. A compose file or a .env hands over an empty value when you chose none (${FTW_LOG_LEVEL:-}).
  • A value that is not a positive number raises ValueError that names the variable (or the argument), when the object is built. A count must be an integer. There is no way to switch a timeout off: a very large value does it.
  • The effective values are logged at INFO when a runner or a worker is built (runner_configured, worker_configured), so that a setting that came from the environment is not invisible.

The settings

Variable Default Argument What it sets
FTW_MAX_CONCURRENT_ATTEMPTS 10 AgentRunner(max_concurrent=) Model attempts running at once, per runner (runner)
FTW_MAX_AGENT_DEPTH 3 AgentRunner(max_depth=) Most agents in one chain of launches. 1 turns launching off
FTW_MAX_AGENT_LAUNCHES 10 AgentRunner(max_launches=) Most launches per attempt of one agent
FTW_MAX_BACKGROUND_JOBS 3 AgentRunner(max_background_jobs=) Most children one attempt may have running in the background
FTW_WORKER_CONCURRENCY 10 JobWorker(concurrency=) Jobs one worker runs at once
FTW_OBSERVER_TIMEOUT 1 s none How long an observer hook may take before the runner goes on (observers)
FTW_WORKER_RECEIVE_TIMEOUT 1 s none How long a worker waits for a message before it looks again whether it is stopping
FTW_WORKER_CANCEL_POLL 1 s none How often a worker asks whether a job it runs was cancelled in another process
FTW_JOB_LEASE 60 s none How long a worker holds a job without renewing it, before another may take it over (submitted jobs)
FTW_HEARTBEAT a third of the job's lease none How often a worker renews the leases of its jobs and of their messages
FTW_QUEUE_LEASE 60 s none How long a message that was received stays invisible to other receivers, in the queues featherweight ships (SqliteQueue)
FTW_QUEUE_MAX_DELIVERIES 3 none How many times SqliteQueue delivers a message before it marks it dead
FTW_JOBS_LOOKUP_TIMEOUT 15 s none How long jobs_lookup may take (submitted jobs)
FTW_SKILL_READ_TIMEOUT 15 s none How long a skill's aread may take (skills)
FTW_DB_PATH featherweight.db the path given to SqliteDatabase The sqlite file
FTW_LOG_LEVEL INFO the level given to setup_logging() The log level

FTW_DB_PATH and FTW_LOG_LEVEL are not numbers and are read where they were, by SqliteDatabase and setup_logging(): an argument wins there too.

What is not configuration

  • How long this call waits is an argument of the call: JobClient.wait(timeout), JobQueue.receive(timeout), JobWorker.stop(grace).
  • A timeout that belongs to a typed definition differs per job or per server, so it is in the definition: a job's timeout, an MCP server's timeout_s.
  • The attachment limits (max_attachments, max_bytes) are class attributes of the streaming agent: they differ per agent, so they are in the definition (attachments). There is no variable for them and no runner argument.
  • A runner's own behaviour in code: max_attempts and retry_delay_s stay arguments of AgentRunner.
  • MemoryQueue(lease=) (in featherweight.testing, for tests) is an argument: the queue kit builds queues with make_queue(lease), and a queue that someone else writes reads its own setting.

Decisions

  • One list and one reader. Before this, some numbers were variables, some were arguments and the limits were both; that made each one a thing to look up. The list is the table above, and featherweight.config reads it.
  • Both ways only where a person changes it by hand. A notebook or a local run should not need an environment to try max_depth=1; nobody sets a lease for one worker, so a lease has no argument and the constructors do not grow a parameter for every knob.
  • The FTW_ prefix on every variable, so that a bare name cannot collide with another tool's in a deployment.
  • Two leases, two variables. The job's lease and the queue's lease have different jobs (submitted jobs) and are set apart.
  • Read once, when built. A value that changed under a running worker would be a cause of failures that cannot be reproduced.
  • No off switch for a timeout, because a timeout that can be turned off is the one that is off when it is needed.
  • Pre-release: no alias. The old names (MAX_CONCURRENT_ATTEMPTS, MAX_AGENT_DEPTH, MAX_AGENT_LAUNCHES) and the removed arguments are gone.

Not supported

  • A configuration file, and a settings object that is passed around.
  • Changing a setting of a running runner or worker.
  • A way to switch a timeout off.

Tests

  • For each setting: the default; the variable; for a "both ways" setting, that the argument wins; a value that is not a number, is zero or is negative raises ValueError that names the variable; an object built before the variable was set does not see it.
  • The table here, the list in featherweight.config and the Configuration table of the guide say the same (a test compares them).
  • The runner and the worker log their effective values when they are built.
  • The old names do nothing.